T6-600 voltage, continuity, and current test and the VoltAlert voltage detector
Measure voltage up to 600 V AC through the open fork, without test lead contact to live voltage. Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A. It will change your job. Safer. Faster. Easier. Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
The next generation VoltAlert AC non-contact voltage testers from Fluke are easy to use — just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there’s voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test for energized circuits in the workplace or at home.
These two electrical testers are paired together in a convenient kit to help electricians and HVAC technicians solve problems faster.
T6-600:
• FieldSense technology for AC voltage, current and frequency measurement without making electrical contact to live voltage1
• 1 - 600 V AC (T6-600) or 1 - 1000 V AC (T6-1000)
• 0.1 - 200 A AC
• True-RMS voltage and current
• Resistance 1 Ω to 2000 Ω (T6-600) or 1 - 100 kΩ (T6-1000)
• Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
• HOLD button temporarily freezes the reading for easy viewing
• Easy to read display with backlight
• Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
• Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase2
1Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
2Register product online within 45 days of purchase to extend warranty to four years. See http://a.fluke.com/registration for details. Two-year additional warranty offer may be discontinued without notice
1AC:
• Voltbeat™ technology and continuous self-test — so you always know it’s working
• Upon detection, tip glows and beeper sounds
• CAT IV 1000 V for added protection
• Expanded range of 200 V - 1000 V AC
• 20 V - 90 V AC control circuit model also available
• Two year warranty
T6-600
Measurement Specifications | ||||||
Function | Requires | Range | Resolution | Accuracy1 | ||
FieldSense AC Voltage True-RMS | No | 600 V | 1 V | +/- (3% + 3 counts), 45 Hz - 66 Hz2, 3 | ||
FieldSense AC Current True-RMS | No | 200.0 A | 0.1 A | +/- (3% + 3 counts) 45 Hz - 66 Hz | ||
Volts AC True-RMS | Yes | 600 V | 1 V | +/- (1.5% + 2 counts) 45 Hz - 66 Hz | ||
Volts DC | Yes | 600 V | 1 V | +/- (1% + 2 counts) | ||
Resistance | Yes | 2000 Ω | 1 Ω | +/-(1% + 2 counts) | ||
Safety |
| 600 V CAT III |
|
| ||
1 +/- ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 y after calibration, at 18°C - 28°C (64°F - 82°F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding. | ||||||
General Specifications | ||||||
Calibration | 1 year calibration cycle | |||||
Dimensions | 61.1 mm x 259.3 mm x 43.8 mm | |||||
Jaw Opening | 17.8 mm | |||||
Weight | 0.35 kg (0.78 lb) | |||||
Temperature | Operating | -10°C - 50°C (14°F - 122°F) | ||||
Storage | -30°C - 60°C (-22°F - 140°F) | |||||
Altitude | Operating | 2,000 m (6,562 ft) | ||||
Storage | 10,000 m (32,808 ft) | |||||
Relative Humidity | 0% - 90%, 5°C - 30°C (41°F - 86°F) | |||||
Battery Type and Life | 2 x AA (IEC LR6); 360 h continuous, typical; 200 h using FieldSense | |||||
Temperature Coefficient | 0.1 x (specified accuracy) / °C for <18°C or >28°C (< 64.4°F or > 82.4°F) | |||||
Safety | IEC/EN 61010-1: Pollution Degree 2 | |||||
Electromagnetic Environment | IEC/EN 61326-1: Portable | |||||
1AC
Specifications | |
Operating Principle | Senses the steady state electrostatic field produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage |
Voltage Sensing Ranges | Nominally 200 V AC - 1000 V AC, 45 Hz - 405 Hz; also a 20 V - 90 V control circuit model |
Detector Tip Style | Blade or round, depending on model |
Light Source | One high intensity red LED |
Safety Rating | CAT IV 1000 V |
IP Rating | IP 40 |
Operating Temperature | -10°C - 50°C |
Operating Humidity Ranges | 0% - 95% (0°C - 30°C) 0% - 75% (30°C - 40°C) 0% - 45% (40°C - 55°C) |
Operating Altitude | 3000 m |
Batteries | Two (2) AA alkaline batteries (included) |
Note: Product does not respond to random electrostatic discharge
Fluke T6-HT6-1AC KIT Electrical Tester, Voltage Tester and Holster - T6-600 Data Sheet 1.4 MB |