` 5623B Precision Resistance Temperature Detector Freezer Probe

Fluke Calibration

5623B Precision Resistance Temperature Detector Freezer ...

Specially sealed from the sensing element to the end of the probe cable, preventing ingress of moisture when exposed to low temperatures

Starting At
$2,406.00 CAD
Normally ships in 4-6 Weeks

Configure   Request Quote

Can We Help You?

CALL US   EMAIL US   CHAT LIVE

Our product experts are here to help you find the right solution for your application!

The 5623B, precision “freezer probe," is specially sealed from the sensing element to the end of the probe cable, preventing ingress of moisture when exposed to temperatures as low as -100°C. The entire assembly withstands temperatures over its full range (-100°C - 156°C), which is ideal for verification of freezers or autoclaves where a thermo-well isn’t available. The 5623B assembly can be fully immersed in fluids when the application may require use in a liquid bath. The 5623B is available in a 6.35 mm (0.25 in) dia. × 125 mm (6 in) long Inconel™ sheath. With accuracy (that includes calibration uncertainty and short-term drift) of +/- 0.05°C over its full range, the 5623B is just right as a secondary standard for calibration of other process sensors.

Most Fluke Calibration readouts make an excellent companion for the 5623B. We recommend the use of the 1523, 1524, 1502A, 1529, or 1560 thermometer readouts.

With each 5623B, you receive a full NVLAP-accredited calibration report. This report includes test data and ITS-90 calibration coefficients to enter into your Fluke Calibration thermometer readout.

• Fully immersible probe assembly to -100°C
• NVLAP-accredited calibration and ITS-90 coefficients included
• Accuracy to +/- 0.05°C over the full range

Resistance Nominal 100 Ω (+/- 0.1 Ω)
Temperature Coefficient 0.003925 Ω/Ω/°C nominal
Temperature Range -100°C - 156°C
Transition Temperature -100°C - 156°C
Drift Rate +/- 0.01°C per year maximum at 0°C, when used periodically at max temperature
Sheath Material Inconel™ 600
Leads PTFE-insulated, silver-plated stranded copper, 22 AWG.
Termination Specify. See Models and Accessories.
Calibration Includes manufacturer's NVLAP-accredited, lab code 200706-0, calibration and table with R vs. T values in 1°C increments from -80°C - 156°C. ITS-90 coefficients included.
Calibrated Accuracy (k = 2) +/- 0.05°C over the full range
Cable Length 6.1 m (20 ft)
Size 6.35 mm dia. x 152 mm (0.25 in dia x 6 in)
Item
Description
Availability
Price
Plastic probe carrying case for probes up to 228 mm (9 in) in length
Normally ships in 4-6 Weeks
$277.00 CAD


Your Recently Viewed Items...